Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.796
Filtrar
1.
J Nepal Health Res Counc ; 21(3): 467-471, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38615219

RESUMO

BACKGROUND: Allergic contact dermatitis is one of the most common forms of skin diseases that require medical intervention. Appropriate detection of allergens by patch test and accurate avoidance of them is the key to management. The objective of this study is to determine the types and frequency of allergens responsible for Allergic contact dermatitis in a tertiary hospital of Nepal. METHODS: Altogether 120 patients with Allergic contact dermatitis were enrolled in the study. Patch test was performed to find out the most common inciting allergen, utilizing the Indian Standard Series of allergens approved by The Contact and Occupational Dermatoses Forum of India. Results were read at 48 and 96 hours. Grading of the reactions was done based on the criteria of the International Contact Dermatitis Research Group. Pattern of reactivity of different allergens was assessed. RESULTS: Of all the patients, 63 (53%) showed positivity to at least one allergen. Nickel sulfate was the most frequent sensitizing agent in 22 (18%) cases, followed by Fragrance mix in 11(9%) and Paraphenylenediamine in 7 (6%) cases. Out of all positive results, Grade 1 positivity was seen in 44 (51%), Grade 2 positivity in 41(47%) and only 2 (2%) cases showed Grade 3 positivity. Mercaptobenzothiazole, Balsam of Peru, Nitrofurazone and Wool Alcohol did not show positive results in any of our patients. CONCLUSIONS: Patch testing helps in the treatment, long term remission, and patient counseling for prevention. Larger scale studies are required to know the sensitivity to allergens in Nepalese population.


Assuntos
Dermatite Alérgica de Contato , Humanos , Alérgenos/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Nepal/epidemiologia , Testes do Emplastro , População do Sul da Ásia
2.
Acta Derm Venereol ; 104: adv19676, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38551376

RESUMO

Allergic contact dermatitis is reported among individuals using continuous glucose monitoring systems and insulin pumps. The aim of this study was to describe contact allergy patterns for allergens in the Swedish baseline series and medical device-related allergens among users. Contact allergy to baseline series allergens and isobornyl acrylate was compared between diabetes patients and dermatitis patients patch-tested at the Department of Occupational and Environmental Dermatology during 2017 to 2020. Fifty- four diabetes patients and 2,567 dermatitis patients were included. The prevalence of contact allergy to fragrance mix II and sesquiterpene lactone mix was significantly higher in diabetes patients compared with dermatitis patients. Of the diabetes patients 13.0% and of the dermatitis patients 0.5% tested positive to sesquiterpene lactone mix (p < 0.001). Of the diabetes patients 7.4% and of the dermatitis patients 2.3% tested positive to fragrance mix II (p = 0.041). Of the diabetes patients 70.4% tested positive to medical device-related allergens. Of the diabetes patients 63.0% and of the dermatitis patients 0.2% were allergic to isobornyl acrylate (p < 0.001). In conclusion, not only medical device-related contact allergies, but also contact allergy to baseline series allergens (fragrance mix II and sesquiterpene lactone mix), is overrepresented in diabetes patients who use medical devices.


Assuntos
Acrilatos , Canfanos , Dermatite Alérgica de Contato , Diabetes Mellitus , Sesquiterpenos , Humanos , Alérgenos/efeitos adversos , Estudos Retrospectivos , Suécia/epidemiologia , Automonitorização da Glicemia , Glicemia , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/induzido quimicamente , Testes do Emplastro , Lactonas
3.
Actas Dermosifiliogr ; 115(4): T331-T340, 2024 Apr.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38331170

RESUMO

BACKGROUND: The epidemiological surveillance of contact dermatitis is one of the objectives of the Spanish Registry of Research in Contact Dermatitis and Cutaneous Allergy. Knowing whether the prevalence of positive tests to the different allergens changes over time is important for this monitoring process. OBJECTIVES: To describe the various temporary trends in allergen positivity in the GEIDAC standard series from 2018 through December 31, 2022. METHODS: This was a multicenter, observational trial of consecutive patients analyzed via patch tests as part of the study of possible allergic contact dermatitises collected prospectively within the Spanish Registry of Research in Contact Dermatitis and Cutaneous Allergy. The data was analyzed using 2 statistical tests: one homogeneity test (to describe the changes seen over time) and one trend test (to see whether the changes described followed a linear trend). RESULTS: A total of 11327 patients were included in the study. Overall, the allergens associated with a highest sensitization were nickel sulfate, methylisothiazolinone, cobalt chloride, methylchloroisothiazolinone/methylisothiazolinone, and fragrance mix i. A statistically significant decrease was found in the percentage of methylisothiazolinone positive tests across the study years with an orderly trend. CONCLUSIONS: Although various changes were seen in the sensitizations trends to several allergens of the standard testing, it became obvious that a high sensitization to nickel, methylchloroisothiazolinone/methylisothiazolinone and fragrances mix i remained. Only a significant downward trend was seen for methylisothiazolinone.


Assuntos
Dermatite Alérgica de Contato , Dermatite Atópica , Humanos , Tiazóis , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Alérgenos/efeitos adversos , Testes do Emplastro , Estudos Retrospectivos
4.
Contact Dermatitis ; 90(5): 486-494, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38348533

RESUMO

BACKGROUND: Current frequency and features for positivity to textile dye mix (TDM) in Spain are unknown. OBJECTIVES: To study the frequency, clinical features and simultaneous positivity between TDM, para-phenylenediamine (PPD) and specific disperse dyes. MATERIALS AND METHODS: We analysed all consecutive patients patch-tested with TDM from the Spanish Contact Dermatitis Registry (REIDAC), from 1 January 2019 to 31 December 2022. Within this group, we studied all selected patients patch-tested with a textile dye series. RESULTS: Out of 6128 patients analysed, 3.3% were positive to the TDM and in 34% of them, the sensitization was considered currently relevant. TDM positivity was associated with working as a hairdresser/beautician and scalp, neck/trunk and arm/forearm dermatitis. From TDM-positive patients, 57% were positive to PPD. One hundred and sixty-four patients were patch-tested with the textile dye series. Disperse Orange 3 was the most frequent positive dye (16%). One of every six cases positive to any dye from the textile dye series would have been missed if patch-tested with the TDM alone. CONCLUSIONS: Positivity to TDM is common in Spain and often associated with PPD sensitization. TDM is a valuable marker of disperse dyes allergy that should be part of the Spanish and European standard series.


Assuntos
Dermatite Alérgica de Contato , Humanos , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Espanha/epidemiologia , Têxteis/efeitos adversos , Testes do Emplastro , Corantes/efeitos adversos
5.
Contact Dermatitis ; 90(5): 507-513, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38351475

RESUMO

BACKGROUND: A global epidemic of allergic contact dermatitis to (meth)acrylates has been described in relation to the widespread use of manicure products. OBJECTIVES: To evaluate the frequency of sensitization to 2-hydroxyethyl methacrylate (2-HEMA) among consecutively patch tested patients with eczema in Spain; the percentage of current relevance; the MOAHLFA index; and, the potential sources of exposure to (meth)acrylates. METHODS: From January 2019 to December 2022, 2-HEMA 2% pet. was prospectively patch tested in 24 REIDAC (Spanish Allergic Contact Dermatitis Registry) centres. RESULTS: Six thousand one hundred thirty-four patients were consecutively patch tested with 2-HEMA 2% pet. 265/6134 (4.3%) were positive. Positive reactions of current relevance were identified to involve 184/265 (69%). The efficiency (number of patch tests needed to detect relevant positive patch test reactions) was 34 (6134/184). The variable 'occupational' was found to be significantly associated with a higher risk for relevant positive reactions to 2-HEMA (OR: 10.9; 95% CI: 8.1-14.9). CONCLUSION: (Meth)acrylate sensitization is a prevalent health issue in Spain. 2-HEMA 2% pet. has been identified to be a highly effective (meth)acrylate allergy marker in the GEIDAC baseline series. The responsible authorities should implement policies guaranteeing accurate labelling of industrial, medical, and consumer materials while ensuring the enforcement of said labelling through appropriate legal means.


Assuntos
Dermatite Alérgica de Contato , Dermatite Ocupacional , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Espanha/epidemiologia , Metacrilatos/efeitos adversos , Acrilatos , Testes do Emplastro
6.
Contact Dermatitis ; 90(5): 445-457, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38382085

RESUMO

Frequent use of methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) and MI in cosmetic products has been the main cause of widespread sensitization and allergic contact dermatitis to these preservatives (biocides). Their use in non-cosmetic products is also an important source of sensitization. Less is known about sensitization rates and use of benzisothiazolinone (BIT), octylisothiazolinone (OIT), and dichlorooctylisothiazolinone (DCOIT), which have never been permitted in cosmetic products in Europe. BIT and OIT have occasionally been routinely patch-tested. These preservatives are often used together in chemical products and articles. In this study, we review the occurrence of contact allergy to MI, BIT, OIT, and DCOIT over time, based on concomitant patch testing in large studies, and case reports. We review EU legislations, and we discuss the role of industry, regulators, and dermatology in prevention of sensitization and protection of health. The frequency of contact allergy to MI, BIT, and OIT has increased. The frequency of contact allergy to DCOIT is not known because it has seldom been patch-tested. Label information on isothiazolinones in chemical products and articles, irrespective of concentration, is required for assessment of relevance, information to patients, and avoidance of exposure and allergic contact dermatitis.


Assuntos
Cosméticos , Dermatite Alérgica de Contato , Desinfetantes , Tiazóis , Humanos , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Dermatite Alérgica de Contato/prevenção & controle , Cosméticos/efeitos adversos , Desinfetantes/efeitos adversos , Europa (Continente)/epidemiologia , Conservantes Farmacêuticos/efeitos adversos , Testes do Emplastro/efeitos adversos
7.
Allergol Immunopathol (Madr) ; 52(1): 93-96, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38186199

RESUMO

Allergic contact dermatitis (ACD) is a more frequent pathology in adults than in children, because, in most cases, allergic sensitization requires a prolonged exposure time to the allergen, mostly months or years. In fact, the actual incidence and prevalence of ACD in children and adolescents is unknown. However, there is a hypothesis that ACD is increasing in the pediatric population. Among the allergens involved in ACD, the frequency of paraphenylenediamine (PPDA) is increasing. PPDA is one of the five most common contact allergens in the general population and one of the 10 most common contact allergens in children. The most relevant sources today are henna tattoos and hair dyes. Currently, European Union legislation limits the use of PPDA in hair dyes and prohibits its use in henna tattoos. Despite this legislation, the use of henna tattoos with PPDA is becoming more frequent in younger ages. We report an early presentation of ACD by PPDA, with a permanent hypopigmented skin area as an aftermath, in a 7-year-old male child. We believe that health authorities should advise against making these tattoos in children.


Assuntos
Dermatite Alérgica de Contato , Tinturas para Cabelo , Criança , Adolescente , Adulto , Masculino , Humanos , Tinturas para Cabelo/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , União Europeia
8.
Contact Dermatitis ; 90(2): 110-115, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37840032

RESUMO

BACKGROUND: Preservatives are a frequent cause of allergic contact dermatitis (ACD) and have caused numerous epidemics. OBJECTIVES: The objective of this study is to determine the prevalence of preservative sensitivity, assess the change in the frequency of sensitivity, identify new preservatives with increased sensitivity rates, and evaluate the situation in Turkey by comparing our findings with current literature. METHODS: A total of 201 patients diagnosed with ACD between 2018 and 2020, were patch tested with the European baseline series and additional seven preservative haptens. The change in the prevalence of sensitivity to each preservative hapten was investigated by comparing the data from the study conducted in our department between 2000 and 2004. RESULTS: Results showed that 17.4% (n = 35) of the patients were positive to preservatives. Comparison with previous data from 2000 to 2004 revealed an increase in the frequency of sensitization. The most prevalent allergen was methyldibromo glutaronitrile (9.5%), followed by methylchloroisothiazolinone/methylisothiazolinone (6.5%), and methylisothiazolinone (5%). CONCLUSION: The increase in preservative sensitivity in Turkey is the most remarkable finding. Although MDBGN was prohibited in cosmetic products, MCI/MI and MI are still widely used. Our findings suggest that awareness of preservative sensitivity should be increased and additional precautions should be taken, also in Turkey, regarding the use of preservatives.


Assuntos
Dermatite Alérgica de Contato , Conservantes Farmacêuticos , Humanos , Alérgenos/efeitos adversos , Cosméticos , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Dermatite Alérgica de Contato/diagnóstico , Haptenos , Nitrilas , Testes do Emplastro/métodos , Conservantes Farmacêuticos/efeitos adversos , Tiazóis , Turquia/epidemiologia
10.
Curr Opin Allergy Clin Immunol ; 24(2): 51-57, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38037883

RESUMO

PURPOSE OF REVIEW: Occupational allergic contact dermatitis (OACD) is an important work-related skin disease. Information about the causative agents comes from many sources, including patch test databases, registries, case series and case reports. This review summarizes new information about common causative allergens and diagnosis. RECENT FINDINGS: Common causes of OACD include rubber components, epoxies and preservatives. New exposure sources for these allergens continue to be described. Often these exposure sources are related to the changing world around us, such as allergens related to smartphones and technology, and personal protective equipment-related exposures during the COVID-19 pandemic. New allergens are also being described, some of which are related to known allergens (e.g. a new epoxy or acrylate component).Accurate diagnosis is critical to effective management of OACD, which may include removing the worker from exposure to the causative allergen. Safety data sheets may not contain complete information and patch testing with specialized series of allergens and workplace materials may be necessary. SUMMARY: This review provides current evidence about causes of OACD and important aspects of diagnosis. This is important for clinical practice to ensure cases of OACD are not missed.


Assuntos
Dermatite Alérgica de Contato , Dermatite Ocupacional , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Pandemias , Dermatite Ocupacional/diagnóstico , Dermatite Ocupacional/epidemiologia , Dermatite Ocupacional/etiologia , Alérgenos , Testes do Emplastro/efeitos adversos
11.
Contact Dermatitis ; 90(3): 253-261, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38038148

RESUMO

BACKGROUND: Ethylenediamine dihydrochloride is a versatile aliphatic amine found in numerous medications and industrial compounds and is a known sensitiser. The sensitization prevalence is affected by geographical and socio-cultural factors. OBJECTIVES: The objectives are to analyse the temporal trend of sensitization to ethylenediamine dihydrochloride in northeastern Italy and to investigate associations with occupations. METHODS: Between 1996 and 2021, 30 629 patients with suspected allergic contact dermatitis were patch tested with the Triveneto baseline series. Individual characteristics were collected through a standardised questionnaire. RESULTS: The overall prevalence of ethylenediamine dihydrochloride sensitization was 1.29% with percentages similar in both sexes. We observed a significant decreasing trend over time (p < 0.001), yielding a sensitization prevalence <1% in recent years. Among departments, residence in Pordenone area was protective for sensitization. No significant associations were observed with specific occupations. We found significant associations between ethylenediamine dihydrochloride sensitization and being 26-35 years old (odds ratio [OR], 1.47; 95% confidence interval [CI]: 1.05-2.08), and sensitization for many haptens, such as paraben mix (OR, 5.3; 95% CI: 3.3-8.5), epoxy resin (OR, 5.1; 95% CI: 3.0-8.7), neomycin sulphate and mercaptobenzothiazole. CONCLUSIONS: Our study showed a downward time trend of ethylenediamine dihydrochloride sensitization in northeastern Italian population and pointed to an update of the Triveneto baseline series.


Assuntos
Dermatite Alérgica de Contato , Dermatite Ocupacional , Etilenodiaminas , Masculino , Feminino , Humanos , Adulto , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Dermatite Ocupacional/epidemiologia , Dermatite Ocupacional/etiologia , Testes do Emplastro , Itália/epidemiologia , Prevalência , Alérgenos
12.
Contact Dermatitis ; 90(3): 245-252, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37987093

RESUMO

BACKGROUND: Monitoring of adverse events induced by cosmetics performed by health authorities, known as cosmetovigilance, has been relied on the collection of case notifications. OBJECTIVES: We aimed to show how a contact dermatitis registry can contribute to the cosmetovigilance of emerging allergens. We used the example of phenylethyl resorcinol, an infrequent allergen with only 6 previous cases reported in Europe and Japan since 2013. METHODS: A systematic search in the Spanish Registry of Contact Dermatitis and Cutaneous Allergy (REIDAC) database was performed to identify patients with positive patch test to phenylethyl resorcinol or cosmetics that contains it between June 2018 and January 2023. We collected the main clinical features of these patients and compared them with those of patients recorded in the registry with similar epidemiological features. RESULTS: Thirteen patients with positive patch test to phenylethyl resorcinol were identified. All the patients were women with a mean age of 42 years (range 32-59) and their lesions were mainly in the face. CONCLUSION: Assessing the importance of infrequent allergens based solely on a case series is difficult. Multicentre registries facilitate the collection of cases and provide appropriate background information for new allergens.


Assuntos
Compostos Benzidrílicos , Cosméticos , Dermatite Alérgica de Contato , Resorcinóis , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Alérgenos/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Espanha/epidemiologia , Estudos Retrospectivos , Cosméticos/efeitos adversos , Testes do Emplastro/efeitos adversos , Sistema de Registros
13.
Contact Dermatitis ; 90(2): 134-142, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37852634

RESUMO

BACKGROUND: Contact allergy rates of linalool and limonene hydroperoxides (HPs) have increased. OBJECTIVES: To demonstrate the patterns of simultaneous positive patch test (PT) reactions and prevalences of multiple contact allergies (MCAs) in patients with contact allergy to linalool and/or limonene HPs. METHODS: A retrospective analysis of consecutive dermatitis patients in 2015-2020 was performed. RESULTS: Of all 4192 patients, 1851 had at least one positive PT reaction. Of these, 410 (22.2%) had MCAs, significantly related to a higher age (p-value = 0.003). Patients with an exclusively positive reaction to linalool HPs but not limonene HPs were shown to have MCAs (p-value <0.001, odds ratio (95% confidence interval) = 4.15 (3.01-5.73)). Patients with simultaneous contact allergies to both linalool and limonene HPs had contact allergies to many other screening and fragrance allergens. CONCLUSIONS: Simultaneous positive PT reactions to allergens in baseline series and fragrances are common in patients with the HPs contact allergy, especially linalool HPs. The pattern of simultaneous PT reactions principally suggested the co-sensitization of the cosmetic allergens.


Assuntos
Monoterpenos Acíclicos , Dermatite Alérgica de Contato , Perfumes , Humanos , Limoneno/efeitos adversos , Monoterpenos/efeitos adversos , Terpenos/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Estudos Retrospectivos , Cicloexenos/efeitos adversos , Alérgenos/efeitos adversos , Peróxido de Hidrogênio/efeitos adversos , Perfumes/efeitos adversos , Testes do Emplastro
14.
J Am Acad Dermatol ; 90(2): 319-327, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37879460

RESUMO

BACKGROUND: Isothiazolinones are a common cause of allergic contact dermatitis. OBJECTIVE: To examine the prevalence of positive patch test reactions to isothiazolinones from 2017-2020 and characterize isothiazolinone-allergic (Is+) patients compared with isothiazolinone nonallergic (Is-) patients. METHODS: Retrospective cross-sectional analysis of 9028 patients patch tested to methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI) 0.02% aqueous, MI 0.2% aqueous, benzisothiazolinone (BIT) 0.1% petrolatum, and/or octylisothiazolinone (OIT) 0.025% petrolatum. Prevalence, reaction strength, concurrent reactions, clinical relevance, and source of allergens were tabulated. RESULTS: In total, 21.9% (1976/9028) of patients had a positive reaction to 1 or more isothiazolinones. Positivity to MI was 14.4% (1296/9012), MCI/MI was 10.0% (903/9017), BIT was 8.6% (777/9018), and OIT was 05% (49/9028). Compared with Is-, Is+ patients were more likely to have occupational skin disease (16.5% vs 10.3%, P <.001), primary hand dermatitis (30.2% vs 19.7%, P <.001), and be >40 years (73.1% vs 61.9%, P <.001). Positive patch test reactions to >1 isothiazolinone occurred in 44.1% (871/1976) of Is+ patients. Testing solely to MCI/MI would miss 47.3% (611/1292) of MI and 60.1% (466/776) of BIT allergic reactions. LIMITATIONS: Retrospective cross-sectional study design and lack of follow-up data. CONCLUSION: Sensitization to isothiazolinones is high and concurrent sensitization to multiple isothiazolinone allergens is common.


Assuntos
Dermatite Alérgica de Contato , Dermatite Ocupacional , Tiazóis , Humanos , Estudos Transversais , Estudos Retrospectivos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Dermatite Ocupacional/diagnóstico , Dermatite Ocupacional/epidemiologia , Dermatite Ocupacional/etiologia , Alérgenos/efeitos adversos , América do Norte , Testes do Emplastro/efeitos adversos , Vaselina , Conservantes Farmacêuticos/efeitos adversos
15.
Dermatitis ; 35(1): 13-23, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37352419

RESUMO

Widespread use of oxidative hair dyes during the past decades has raised questions on the potential allergy reactions and their management, as well as prevention measures for both professionals and consumers. Allergic contact dermatitis can be elicited by various hair dye-related allergens, though the main problem remains with p-phenylenediamine and related aromatic amines. If allergy is suspected, patch testing identifies the responsible hapten. Individuals sensitized to specific permanent hair dyes substances should avoid the exposure to these chemicals, but also be aware of possible cross-sensitization to other similar compounds. Cross-reactions detected in patch-tested populations indicate that one cannot safely use alternatives, although cross-reactivity is not always clinically relevant. An open application hair dye allergy self-test is recommended by manufacturers for early detection of allergy predisposition in consumers, although the lack of standardized conditions makes the efficacy of this process doubtful. Appropriate use of hand gloves, especially nitrile, is the most efficient prevention measure for professional hand eczema. In this systematic review, we focus on cross-reactions among hair dye-related allergens and make an attempt to answer some, frequently encountered by physicians, questions, while presenting the prevalence of the hair dye-related allergens.


Assuntos
Dermatite Alérgica de Contato , Tinturas para Cabelo , Humanos , Alérgenos/efeitos adversos , Alérgenos/química , Tinturas para Cabelo/efeitos adversos , Tinturas para Cabelo/química , Prevalência , Fenilenodiaminas/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Testes do Emplastro
16.
Contact Dermatitis ; 90(2): 143-152, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37752672

RESUMO

BACKGROUND: Occupational contact dermatitis (OCD) is a common occupational disease. Atopic dermatitis (AD) is a known risk factor for OCD. OBJECTIVES: To determine the prevalence of previously diagnosed AD among young workers with recognized OCD and assess its impact on OCD prognosis. METHODS: A retrospective cohort study. A questionnaire was sent to 6251 workers with recognized OCD who were under 35 years at notification (response rate: 47%). Of the respondents, 2392 answered a question about previous doctor-diagnosed AD and were included in the study. Eczema severity, occupational consequences and quality of life were examined using statistical analyses comparing workers with and without previously diagnosed AD. RESULTS: The prevalence of previously diagnosed AD was 41.8% (95% CI: 39.8-43.8). Women had a higher AD prevalence, and workers with AD reported OCD at a younger age. Workers with AD reported more frequent and severe eczema symptoms and had a higher risk of OCD negatively affecting job and occupation choices. Health-related quality of life was more adversely affected in workers with AD. CONCLUSIONS: AD significantly impacts severity and has long-term consequences for young people with OCD. Targeted prevention strategies need to be developed.


Assuntos
Dermatite Alérgica de Contato , Dermatite Atópica , Dermatite Ocupacional , Eczema , Humanos , Feminino , Adolescente , Dermatite Atópica/epidemiologia , Dermatite Atópica/complicações , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Dermatite Alérgica de Contato/diagnóstico , Qualidade de Vida , Estudos Retrospectivos , Dermatite Ocupacional/epidemiologia , Dermatite Ocupacional/etiologia , Dermatite Ocupacional/diagnóstico , Eczema/complicações
17.
Contact Dermatitis ; 90(2): 116-125, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37735996

RESUMO

BACKGROUND: Rubber accelerators are used in the production of rubber gloves and may cause contact allergy. OBJECTIVES: To estimate long-term trend and prevalence of contact allergy to rubber accelerators for a 30-year period in Denmark, high-risk occupations, and exposures. METHODS: Data from all patients with contact dermatitis consecutively patch tested at the department of Skin and Allergy Gentofte hospital with the rubber accelerators from the European baseline series (EBS) from 1990 to 2019, were analysed. Further, patients under suspicion of rubber accelerator contact allergy were additionally patch-tested with rubber accelerators from the specialised rubber series from 2005 to 2019 and these were additional extracted. RESULTS: The overall prevalence of contact allergy to one or more of the rubber accelerators from the EBS series was 2.7% with a significant decline in the first 12-years, followed by a stable frequency in the past 18-years. Associations with occupational contact dermatitis, hand dermatitis, and leg/foot dermatitis were found. Wet-work occupations were most often affected and gloves the most frequent exposure. CONCLUSIONS: Contact allergy to one or more of the rubber accelerators from the EBS is frequent and has been unchanged for several decades, which calls for prevention.


Assuntos
Dermatite Alérgica de Contato , Dermatite Ocupacional , Eczema , Hipersensibilidade ao Látex , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Borracha/efeitos adversos , Testes do Emplastro/efeitos adversos , Dermatite Ocupacional/etiologia , Dermatite Ocupacional/complicações , Hipersensibilidade ao Látex/epidemiologia , Eczema/epidemiologia , Eczema/complicações , Dinamarca/epidemiologia
18.
Contact Dermatitis ; 90(3): 262-265, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38093676

RESUMO

BACKGROUND: Over the last 10 years, allergic contact dermatitis (ACD) from acrylate-containing nail cosmetics (acrylic nails, gel nails, gel nail polish) has been reported repeatedly. OBJECTIVES: To investigate the frequency and clinical features of ACD in nail cosmetics in a university hospital in Amsterdam, The Netherlands. PATIENTS AND METHODS: A retrospective study in patients diagnosed with ACD from acrylate-containing nail cosmetics at the Amsterdam University Medical Centers between January 2015 and August 2023. RESULTS: Sixty-seven patients, all women, were diagnosed with ACD from nail cosmetics, representing 1.6% of all individuals and 2.3% of all women patch tested in this period. Sixty-five of sixty-seven (97%) subjects had a positive patch test to 2-hydroxyethyl methacrylate (HEMA). Forty-nine patients (73%) were consumers and 18 (27%) were professional nail stylists. The sites most frequently affected with dermatitis were the fingers (79%), hands (40%) and the head and/or neck. Avoidance of contact with acrylate-containing products resulted in complete clearing of dermatitis in 80% of patients. CONCLUSIONS: ACD from acrylate-containing nail cosmetics is frequent in women patch tested in Amsterdam. Nearly all were identified by a positive patch test to 2-hydroxyethyl methacrylate in the (meth)acrylate series or the European baseline series.


Assuntos
Cosméticos , Dermatite Alérgica de Contato , Humanos , Feminino , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Estudos Retrospectivos , Unhas , Metacrilatos/efeitos adversos , Acrilatos/efeitos adversos , Cosméticos/efeitos adversos , Testes do Emplastro/métodos
19.
Dermatitis ; 35(1): 43-48, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38011689

RESUMO

Background: Botanicals are increasingly incorporated into skincare products. Although allergic contact dermatitis due to botanicals is recognized, data describing the prevalence of positive patch tests to botanicals are sparse. Objective: To report the Mayo Clinic experience of patch testing to selected botanical products in the standard, extended standard, fragrance, and plant series. Methods: IRB-approved retrospective study of the Mayo Clinic experience with patch testing to botanicals from 1997 to 2017. Results: In total, 12,169 people were patch tested to botanicals in the standard, extended standard, fragrance, and plant series; 4032 were men and 8137 were women. The mean age of the population tested was 54 (standard deviation 17.7) years. Almost 11% (1320/12,169) of the patch-tested population exhibited positive reactions to at least 1 botanical agent. Myroxylon pereirae resin 25% was the most common positive allergen in the series. Patients who had positive reactions to at least 1 botanical agent were more (19.8%) likely to have a positive reaction to at least 1 additional botanical than those patients who did not have any positive tests. Most patients presented with generalized involvement (334) or involvement of the hands (284) or face (232). Conclusion: Physicians should be aware of the high prevalence of allergic contact dermatitis and patch test positivity associated with botanical products.


Assuntos
Dermatite Alérgica de Contato , Perfumes , Masculino , Humanos , Feminino , Adolescente , Testes do Emplastro/métodos , Estudos Retrospectivos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Alérgenos/efeitos adversos , Perfumes/efeitos adversos
20.
Contact Dermatitis ; 90(1): 51-59, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37750414

RESUMO

BACKGROUND: Footwear contact allergy is caused by exposure to allergens in shoes. The prevalence and common allergens vary by region and time due to differences in customs and lifestyle. OBJECTIVES: To determine the clinical characteristics and common allergens of patients with footwear-related allergic contact dermatitis (ACD) who attended Siriraj Hospital in Bangkok, Thailand, between 2001 and 2020. METHODS: The medical records of 247 patients with clinically suspected footwear dermatitis who underwent patch testing were reviewed. RESULTS: The prevalence of ACD to footwear was 1.8%. Females were predominant (71.6%). The three most common allergens were carba mix (7.7%), mercapto mix (6.9%) and potassium dichromate (6.9%). According to the allergens found, rubber (14.2%), adhesives (7.7%) and leathers (6.9%) were the three most common groups. Dorsal-limited skin lesions were significantly associated with footwear ACD. CONCLUSION: Rubber and leather allergens were still the most common culprit allergens. Dermatologists should keep up-to-date on common allergens in footwear and emerging allergens to include in patch test series.


Assuntos
Dermatite Alérgica de Contato , Dermatoses do Pé , Feminino , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Alérgenos/efeitos adversos , Prevalência , Borracha , Tailândia/epidemiologia , Dermatoses do Pé/epidemiologia , Dermatoses do Pé/etiologia , Testes do Emplastro/efeitos adversos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...